PRODUCT DESCRIPTION:
TL8400 is a one component water based acrylic sealer that offers excellent resistance to water blushing without the objectionable solvent odors associated with solvent based sealers. This product has a fast set time and good stain resistance.
RECOMMENDED FOR:
Recommended for sealing concrete or cement. Do not use in immersion service or constant chemical exposure areas.
SOLIDS BY WEIGHT:
25% (+/- 2%)
SOLIDS BY VOLUME:
21% (+/- 2%)
VOLATILE ORGANIC CONTENT:
VOC less than 84 g/l
COLORS AVAILABLE:
This product is available in a clear only
RECOMMENDED FILM THICKNESS:
3-4 mils wet (0.5 – 1.0 mils dry)
COVERAGE PER GALLON:
401-534 square feet @ 3-4 mils wet thickness
PACKAGING INFORMATION
This product is available in 1 gallon, 5 gallon and 50 gallon containers. (volumes approximate)
MIX RATIO:
One component product, simply stir before using
SHELF LIFE:
1 year in unopened containers
ABRASION RESISTANCE:
Taber adrasor CS-17 calibrase wheel with 1000 gram total load and 500 cycles = 80 mg loss
IMPACT RESISTANCE:
Gardner Impact, direct = 50 in.lb. (passed)
FLEXIBILITY:
No cracks on a 1/8” mandrel
ADHESION:
395 psi @ elcometer (concrete failure, no delamination)
VISCOSITY:
Less than 200 cps (typical)
DOT CLASSIFICATIONS:
Not regulated
PEEL ADHESION:
Excellent
CURE SCHEDULE: (70°)
tack free (dry to touch)…………………………………… 1-2 hours
recoat or topcoat…..……………………………………….. 2-4 hours
light foot traffic………………………………………………3-5 hours
full cure (heavy traffic)… ………………………………….2-3 days
APPLICATION TEMPERATURE:
60-100 degrees F with relative humidity below 85%
CHEMICAL RESISTANCE:
REAGENT RATING
Gasoline 1
Brake fluid 1
Used motor oil 5
DI water 5
Rating key: (film damage) 1 = severe -> 5 = no damage.
STAIN RESISTANCE:
REAGENT RATING
Kool-Aid 10
Mustard 10
Chocolate 10
Ketchup 10
Coal Tar 2
Rating key: 10 = excellent stain resistance -> 0 = no stain resistance.
PRIMER:
None required.
TOPCOAT:
None required. Multiple coats of this product are compatible.
LIMITATIONS:
Clarity of color or gloss may be affected by high humidity, low temperatures or chemical exposure. Lighting like sodium vapor lights may affect color.
For best results use a good quality 3/8” nap roller.
Slab on grade requires moisture barrier.
Substrate temperature must be 5°F above dew point
All new concrete must be cured for at least 30 days
Do not apply this product to areas where there is standing water, damp concrete can be coated.
Too thick of an application may result in solvent entrapment and subsequent product failure.
Physical properties listed on this technical data sheet are typical values and not specifications.
See reverse side for application instructions.
See reverse side for limitations of our liability and warranty.